Pulsar Plus Pro OEM Kit – High Resistance Grounding OEM Kit
Line to ground faults are the cause of 98% of all plant electrical
failures. With increased attention industry-wide to lowering the potentially deadly effects of arcing faults, tackling the problem at its
source remains the surest method of increasing your network’s
reliability. Downtime costs in both productivity and profits, and Post
Glover’s Pulser Plus Pro keeps plants running 24/7/365.
The benefits of high resistance grounding have long been recognized
when
compared
to ungrounded or solidly grounded systems. Post
Glover’s Pulser Plus Pro is the only digital high
resistance grounding system with pulsing
available today. Available in an OEM kit suitable
for mounting in low or medium voltage switchgear
cubicles or standard MCC’s, its ease of
installation, top-level factory support and overall
superiority make this the easy choice when the
customer requires a pulsing system for complete
ground protection.
Features of the Pulser Plus Pro
Adjustable Pulse Rate
The pulsing signal can be adjusted from 10 pulses
per minute to 50 pulses per minute, permitting
differentiation between noise and leakage currents.
Loss of Ground Protection
While rare, a resistor failure can rob you of the
benefits of the high resistance grounding system.
Using the normally present leakage current, resistor
failure can be detected and alarms sounded based on
fundamental under-current or under-voltage settings.
Adjustable time delays
Two separate time delay settings, one each for
fundamental and third harmonic settings, prevent
nuisance alarms or trips.
Generator winding protection
All generators produce a small amount of third
harmonics caused by fractional pitch windings. In the
event of a fault near the neutral of a wye generator,
these values will drop. Separate set-points for third
harmonic under-current and under-voltage levels can
be used to alarm this condition.
Harmonic protection
Should normally low third harmonic content increase
to potentially damaging levels, over-current and overvoltage
levels are provided to allow for alarm
purposes.
Communications
Factory installed options provide the ability to
integrate into network monitoring and protection
systems via RS232, Modbus or Ethernet protocols.
Form ‘C’ contacts
Three sets of dry contacts are included for indication
of system changes. One set each is provided for
ground fault, high harmonic content and loss of
ground indication.
The OEM kit, designed for use at 600 volts and below, consists of
three parts: a Front Control Plate, the Internal Control Plate and an
enclosed resistor suitable for remote mounting.
All settings can be accessed and adjusted on the display interface
module. This module can also be configured to display system
status, such as fundamental current and voltage as well as third
harmonic levels.
The Front Control Plate is designed to be installed over a cut-out of
dimensions 17” high by 13” wide. This is compatible with most OEM
switchgear manufacturers. A rectangular shaft couples the
disconnect switch handle on the Front Control Plate to the switch
block on the Internal Control Plate when the cubicle door is closed. The distance between the
plates is set at installation, and the shaft can be cut to length. The distance between the two plates
is typically around 12”.
The control power transformer, shown here mounted
on the Internal Control Plate, is an available option.
Cabling between the display interface module and the
controller is factory supplied. A serial cable is sized to
allow for a range of installation possibilities. Custom
lengths are available should they be required.
All customer connections, such as the form ‘C’ contacts, are made on the supplied terminal strip. The
controller is pre-wired to the strip, simplifying
installation and limiting potential mistakes.
The grounding resistor itself is shipped loose and
suitable for mounting on top of the switchgear cabinet.
Approximate resistor dimensions are 29” wide by 18” long by 29” high. The standard enclosure is
NEMA 3R with a powder-coated ANSI-61 gray finish, made of mill galvanized steel. Stainless steel
enclosures are also available upon request, as are open mounted units for installation inside
existing cabinets.
Save time and money using Post Glover’s pre-engineered, easy to install OEM kit. As the industry’s
leading experts in high resistance grounding, we are constantly pushing the technology and product
forward. Trust Post Glover to deliver faultlessly.
| Feature |
Analog |
Digital |
| Communications |
No |
Yes |
| Data logging |
No |
Yes |
| Real-time trending |
No |
Yes |
| Immune to harmonics |
No |
Yes |
| Low cost - space |
No |
Yes |
| Low cost - wiring |
No |
Yes |
| Easy to install |
No |
Yes |
| Accurate |
No |
Yes |