Load Bank Resistors
   

Load Bank Resistors

Post Glover load bank resistors are systems that provide resistive
electrical loads for testing critical power supply sources such as back-up or standby generators and UPS (Uninterruptible Power Supply) systems at hospitals, data centers and industrial sites. Typical applications using Load Banks include:
  • Testing battery systems
  • Periodic testing of standby engine generator sets
  • Factory testing of engine generator sets
  • UPS System testing
  • Balancing diesel generator loads for cleaner air emissions

Being first a manufacturer of power resistors, Post Glover has a vast array of resistor elements to choose from. This allows us to offer the best possible technical and economic solution for your particular loadbank application. Our stationary convection or fan cooled load banks, based on our advanced element design, allow more kW in a smaller package.

Post Glover's standard Load Bank offering includes Suitcase Load Banks , Portable Load Banks , Radiator Mounted Load Banks and Stationary Load Banks.

load bank
   
suitcase load banks

Control & Fan Power

  • Fan Power Requirements (supplied by user)
    • 208-230 VAC, 3 phase, 60 Hz for 208 VAC units
    • 460 VAC, 3 phase, 60 Hz, for 480 and 240 / 480 VAC units
  • Control Power Requirements (supplied by user)
    • 120 VAC, 1 phase, 60 Hz

Standard Features
 

  • Resistive loadbank elements including: spiral wound, wirewound
    or edgewound stainless steel resistor elements
     
  • 480 VAC or 240 VAC, 3 Phase, 60 Hz, configured for Delta connection
     
  • Fan cooled
     
  • Loads up to
     
  • NEMA 1 enclosure. Mill galvanized finish
     
  • Main line fuse protection
     
  • 5kW or 50kW Step Resolution
     
  • Control Panel, integral to enclosure, including
     
    • Load step ON / OFF switches
       
    • Master load switch
       
    • Main power ON / OFF switch
       
    • Fan start / stop push button
       
    • Voltage selector switch (Dual voltage models only)
       
    • Blower ON indicator
       
    • Air Flow indicator
       
    • Temperature sensing switch
       
    • Differential Pressure switch
   

Available Optional Features

  • Wye Configuration
  • 208, 240 or 600 VAC Configuration
  • 240/480 VAC Configuration
  • NEMA 3R, mill galvanized finish enclosure for resistor unit
  • NEMA 3R radiator (excluding exhaust hood)
  • UL Listing
  • Load step branch fuse protection
  • Digital metering for Voltage, Amps, Hz, kW
  • Analog Voltmeter
  • Analog Ammeter
  • Data Logging
  • Automatic load leveling
  • Reverse Power
  • Load Dump
  • Heated enclosure
  • Remote Control Panel (NEMA 1)
  • Remote Control Panel (NEMA 3R)

 

More Information:
POST GLOVER RADIATOR MOUNTED LOAD BANKS TECH SHEET LB104-07
POST GLOVER PORTABLE LOAD BANKS TECH SHEET LB204-07
POST GLOVER STATIONARY LOAD BANKS TECH SHEET LB304-07
POST GLOVER SUITCASE LOAD BANKS TECH SHEET LB404-07

Load banks

load bank resistors